Hỗ trợ trực tuyến

Hỗ trợ trực tuyến

An Toàn, PCCC
Skype Me!
0908.994504
Điện - Viễn Thông
Skype Me!
Tel: 0906 31 64 66
Kỹ thuật
Skype Me!
Đối tác
 RY-S110 (S110D) Signal level meter
RY-S110 (S110D) Signal level meter
RY-S110 / S110D Signal level meter

Doulbe channel,  A/V,  C/N, 
Average Power, Trunk line Voltage

Giá: vui lòng liên hệ
  • Thông tin chi tiết
  • S110/S110D Signal Level Meter is an instrument used for the construction and maintenance of analog TV / digital TV, and the measurement of TV signal level and power level. It is widely applied in the routine maintenance of the CATV system. S110/S110D Signal Level Meter is compatible to both analog / digital channels, with strong comprehensive performances; it employs high brightness backlight operating modes, with clear LCD screens, dual-channel measurement display, so it is convenient and pragmatic; besides, numeric keypad input allows it easy to operate; S110/S110D is a compact, small light-weight portable signal level measuring
     
    Signal Lever Meters correlation table
    Model No
    Constellation
    Main Parameter
    RY-S110/S110D
    No
    Doulbe channel,  A/V,  C/N, Average Power, Trunk line Voltage,
    RY-S128/S128D
    No
    Spectrum,  Channel Power,  Tilt , A/V,  C/N, Average Power, Trunk line Voltage,
    RY-S200/200D
    No
    MER, BER,  Tilt , A/V,  C/N, Average Power, Trunk line Voltage,
    RY-S1127/RY-S1127DQ
    Yes
    Spectrum, MER, BER , Tilt , Channel Power, A/V, C/N, Average Power, Trunk line Voltage
    RY-S1130/RY1130DQ
    Yes
    Advanced spectrum, Full automatica scan , MER, BER ,  Tilt  , V/A,C/N , Average Power ,Channel Power, Trunk line Voltage, Threshold, Alarms
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     

    Technical Data
    Model No
    RY-S110
    RYS110D
    Frequency / channel
     
     
    Frequency scope
    47~870MHz
    5~870MHz
    Channel
    U.S. Standard Channel USA STD-CATV
                U.S. digital standard channels USA STD-CATV
    Frequency accuracy
    +50 * 10E-6 (20 oC +5 oC)
    Level measurement
     
    Measuring range:
    30dBuV ~ 120 dBuV
    Measurement accuracy
    +2dB (20 oC +5oC)
    Resolution
    0.5dB
    Carrier-to-noise       ratio measurement
     
    Measuring range
    20dB ~ 50 dB
    Signal input range
    >=85dBuV
    Measurement accuracy
    + 3dB (20oC +5oC)
    Channel scan
    150
    Voltage measurement
     
    Input range
    1 ~ 100V (AC / DC)
    Measurement accuracy
    +2V
    Resolution
    1V
    Power supply
     
    battery
    7.2V/1500mAH rechargeable battery
    AC Supply:
    AC 90V-220V 50Hz-60Hz
    Working time
    6h
    Charging time
    3h