Perkins Genset
This page shows you our diesel generator sets powered by Perkins engines.
AOSIF has over 10 years experience as a diesel generator set
manufacturer. We are the authorized OEM partner of Perkins Engine
Company and are able to offer Perkins engine powered genset at wide
power supply solution. Our diesel gensets are manufactured in line with
ISO8525, GB/T2820-97, CE, Soncap and SGS standards and under
international ISO9001 and ISO14001 quality and environmental management
systems. Due to this, they are acceptable by clients in more than 50
countries.
Main components
1. Engine
Our Perkins Genset is powered by UK technology Perkins engine. The
Perkins diesel genset can be equipped with different types of water
cooled diesel engines. To illustrate, there are diesel engines with
mechanical governor, electrical governor, and electronic fuel injection
system. There are also natural aspirated engine and turbo charged engine
for customers to choose from. 3-8 cylinder in-line engine and 12-16
cylinder V-engine are optional.
2. Alternator
A standard Perkins genset is set with a Leroy Somer brushless alternator
which has automatic voltage regulation function, protection grade at
IP23, H class insulation, and is manufactured according to IEC
34.1/34.2/34.5, BS4999&5000, NEMA MG1.22, VDE0530, NFC51.111,
ISO8528.3, CSA, UL1446, UL508, and CSA/UL standards. Our Perkins engine
powered diesel generator set can also be optionally equipped with
Stamford, Marathon, and economic type alternators.
3. Silent canopy
Our Perkins genset is manufactured with a silent canopy. The canopy is a
strong steel construction that prevents from damage and is
weatherproof, using high quality acoustic material to keep the noise
down to maximum 75db(A)/7 M, and meanwhile, it has a lifting ear
(forklift) for easy transportation of the diesel generator set. There is
also an inside light for daily maintenance.
4. Others
Two types of circuit break, MCCB and ACB, are available for the diesel
genset. In addition, the diesel generating set can be optionally
designed with manual and automatic digital control panel or
synchronization panel. Its AMF with Automatic Transfer Switch controller
will help the diesel genset to start up automatically.
The prime power of the Perkins genset ranges from 9KVA to 2058KVA, and the standby power ranges from 10KVA to 2263KVA. In terms of operating voltage, we offer the generators in 220v - 240v, 380V-415V (440V). Other voltages are available upon request.
Perkins Genset Specifications
Genset model | Engine model | Prime power KW/KVA | Standby Power KW/KVA | Fuel Consumption ≤g/kw.h | Dimension mm | Weight kg | Detailed Data |
AP10 | 403D-11G | 7/9 | 8/10 | 252 | 1280×500×860 | 330 | Liên hệ |
AP14 | 403D-15G | 10/13 | 11/14 | 264 | 1280×500×950 | 390 | Liên hệ |
AP22 | 404D-22G | 16/20 | 18/23 | 243 | 1420×500×1000 | 470 | Liên hệ |
AP33 | 1103A-33G | 24/30 | 27/33 | 211 | 1520×650×1200 | 750 | Liên hệ |
AP50 | 1103A-33TG1 | 36/45 | 40/50 | 215 | 1520×650×1200 | 770 | Liên hệ |
AP66 | 1103A-33TG2 | 48/60 | 53/66 | 220 | 1520×650×1200 | 770 | Liên hệ |
AP72 | 1104A-44TG1 | 52/65 | 58/72 | 208 | 1800×650×1200 | 840 | Liên hệ |
AP88 | 1104A-44TG2 | 64/80 | 71/88 | 208 | 1800×650×1200 | 850 | Liên hệ |
AP110 | 1104C-44TAG2 | 80/100 | 88/110 | 208 | 1850×700×1200 | 1120 | Liên hệ |
AP150 | 1006TAG | 108/135 | 120/150 | 212 | 2250×800×1280 | 1200 | Liên hệ |
AP165 | 1006TAG2 | 120/150 | 132/165 | 223 | 2300×900×1560 | 1400 | Liên hệ |
AP220 | 1306C-E87TAG3 | 160/200 | 176/220 | 209 | 2530×900×1560 | 1640 | Liên hệ |
AP248 | 1306C-E87TAG4 | 180/225 | 200/250 | 204 | 2530×900×1560 | 1725 | Liên hệ |
AP259 | 1306C-E87TAG5 | 188/235 | 206/259 | 206 | 2530×900×1560 | 1800 | Liên hệ |
AP275 | 1306C-E87TAG6 | 200/250 | 220/275 | 212 | 2530×900×1560 | 1800 | Liên hệ |
AP344 | 2206C-E13TAG2 | 250/313 | 275/344 | 196 | 3050×1110×1850 | 3020 | Liên hệ |
AP385 | 2206C-E13TAG2 | 280/350 | 308/385 | 196 | 3050×1110×1850 | 3020 | Liên hệ |
AP413 | 2206C-E13TAG3 | 300/375 | 330/413 | 196 | 3100x1100x1850 | 3100 | N/A |
AP440 | 2206C-E13TAG3 | 320/400 | 352/440 | 196 | 3100×1110×1850 | 3150 | Liên hệ |
AP495 | 2506C-E15TAG1 | 360/450 | 396/495 | 216 | 3360×1120×1900 | 3300 | Liên hệ |
AP550 | 2506C-E15TAG2 | 400/500 | 440/550 | 211 | 3360×1120×1900 | 3350 | Liên hệ |
AP605 | 2806C-E18TAG1A | 440/550 | 484/605 | 203 | 3215×1540×2100 | 3650 | Liên hệ |
AP646 | 2806C-E18TAG1A | 470/588 | 517/646 | 216 | 3300x1540x2100 | 3700 | N/A |
AP688 | 2806A-E18TAG2 | 500/625 | 550/688 | 198 | 3320×1540 ×2100 | 3880 | Liên hệ |
AP715 | 2806A-E18TAG2 | 520/650 | 572/715 | 202 | 3320x1540x2100 | 3880 | N/A |
AP798 | 4006-23TAG2A | 580/725 | 638/798 | 199 | 3780×1710×2180 | 4900 | Liên hệ |
AP825 | 4006-23TAG3A | 600/750 | 660/825 | 210 | 3780x1710x2180 | 4900 | N/A |
AP880 | 4006-23TAG3A | 640/800 | 704/880 | 210 | 3780×1710×2200 | 4960 | Liên hệ |
AP1100 | 4008TAG2A | 800/1000 | 880/1100 | 208 | 4800×2030×2170 | 7100 | Liên hệ |
AP1375 | 4012-46TWG2A | 1000/1250 | 1100/1375 | 211 | 5100×2050×2400 | 8600 | Liên hệ |
AP1650 | 4012-46TAG2A | 1200/1500 | 1320/1650 | 201 | 5310×2050×2400 | 9500 | Liên hệ |
AP1925 | 4016TAG | 1400/1750 | 1540/1925 | 205 | 5900×2300×3000 | 14500 | Liên hệ |
AP2030 | 4016TAG1A | 1476/1845 | 1624/2030 | 205 | 5900×2300×3000 | 14500 | Liên hệ |
AP2200 | 4016TAG2A | 1600/2000 | 1760/2200 | 209 | 6000x2300x3000 | 14800 | N/A |